• https://www.orecco.com/wp-content/uploads/2019/05/22kv-ring-main-unit-570.jpg

22KV Ring Main Unit

22kv ring main unit (RMU) is three phases, AC50/60HZ with rated operating voltage 22kv, mainly used in power plants, small and medium generator, power transmission, industrial and mining enterprises, power distribution and power systems.

With the adoption of the modular design, 22kv ring main unit (RMU) can be fixed or extended, it is suitable for the end user or network, meanwhile meets the requirement of all kinds of power distribution substations, compact substations, cable branch cabinets. It has advantages of the compact structure, safety, reliability, longevity, and free-maintenance.

The 22kv ring main unit is composed of a switch room, a fuse room, an operating mechanism room and a cable room (chassis).

The switching chamber of the 22kv ring main unit is composed of various functional circuits (including grounding switches and load switches) sealed in the metal casing and bus bars between the circuits.

The load switch of 22kv ring main unit adopts a compressed air blown structure, which has strong arc extinguishing capability and does not affect the phase and ground insulation. The moving and static contacts all have arc contacts, which greatly increases the number of breaks.

Prevent misuse and effectively protect people and equipment, the vacuums load switch used in this 22kv ring main unit is high-voltage switchgear with three stations. That is, isolation, closing, grounding, the isolating switch and the grounding switch have visible fractures, and the load switch and the isolating switch have the function of automatic linkage, that is, when the vacuum load switch is disconnected, the isolation switch is automatically disconnected to form a visible fracture, when the vacuum When the load switch is closed, the isolation switch automatically closes first;

Ring6 24KV C-module F-module v-module
Switch disconnector Earthing switch Switch-fuse disconnector Downstream earthing switch Vacuum circuit-breaker Earthing switch/ disconnector
Rated voltage kV 12/17, 5/24 12/17,5/24 12/17,5/24 12/17,5/24 12/17,5/24 12/17,5/24
Rated frequency 5) Hz 50/50/50 50/50/50 50/50/50 50/5 0/50 50/50/50 50/50/50
Power frequency withstand voltage kV 284)/38/50 284)/38 /50 284,/38 /50 284,/38 /50 284)/38/50 284)/38/50
Lightning impulse withstand voitage kV 95/95/125 95/95/125 95/95/125 95/95/125 95/95/125 95/95/125
Rated normai current A 6 30/630/630 2001) 200/200/200
Breaking capacities:
-active load A 630/630/630
-closed loop A 650/650/650
-offload cable charging A 140/140/140
-offload transformer A 20/20/20
-earth-fault A 205/160/160
-earth-fault cable charging A 117/91/91
-short-circuit breaking current kA see2) 16/16/16
Marking capacity kA 52,5/40/40 52,5/40/40 see2) 5 12,5/12,5/12, 40/40/40 40/40/40
Short tirne current 3 sec,3) kA 21/16/16 21/16/16 16/16/16 16/16/16

1) Depending on the current rating of the fuse-link
2) Limited by high voltage fuse-links
3) Maximum rating for bushings Interface C (400 series bolted)
4) GOST version is available with 42kV power frequency to withstand voltage
5) For rated frequency 60Hz de-rating for current parameter needs to be applied

CEO Note

Hey! This is Tony, the CEO of Orecco Electric. Thanks for visiting our website and I hope to be a friend with you. I have 20 years experience in electric power transmission for primary distribution and secondary distribution, I would like to share my experience with you in this field, please contact me to discuss when you have any question about our products, I’m happy to help you. I provide free consultant for many clients, and if you need any help on power transmission, reach me any with with blow button.

Related Products

11KV Sf6 Ring Main Unit
11KV Sf6 Ring Main Unit
33KV RMU Switchgear
33KV RMU Switchgear
Indoor Vacuum Circuit Breaker
Indoor Vacuum Circuit Breaker
Outdoor Vacuum Circuit Breaker
Outdoor Vacuum Circuit Breaker

Become An Expert When Importing Medium Voltage Electrical Equipments

Here will be the most detailed and professional basics focusing on electrical switchgear.
You could learn the ultimate guide to know the working principle of SF6 gas insulated switchgear from here.
Air circuit breaker and vacuum circuit breaker with the same function as breaking, but their big difference you must know to select the correct one for your project.
Here is the most comprehensive tips for you to know the difference between the power transformer and distribution transformer.